Voltage | Coil Termination | Manufacturer PN | Part No. |
---|---|---|---|
12V | Coil Common to NO | 70 111226 5B1 | 11-03161 |
(Battery Solenoid) - Applicable to all homebuilts. Continuous duty. 12V and 24V. NOT FOR CERTIFIED AIRCRAFT |
should work good
MASTER RELAY 111-226
MASTER RELAY 111-226
MASTER RELAY 111-226
Received promply as ordered
MASTER RELAY 111-226
Dont trust your life to a cheap chi-com solenoid. Good stuff
MASTER RELAY 111-226
Fast shopping and great service
MASTER RELAY 111-226
She was great whom ever I had talked to.
MASTER RELAY 111-226
Same, as the one that failed . To early to rate.
MASTER RELAY 111-226
I bought this at Oshkosh 2022. Installed it and flew home. Worked as advertised. The service at Oshkosh was remarkable. Thank you!
MASTER RELAY 111-226
Everything is perfect about the order. I got the right part and it arrived faster than the estimate. I suppose a schematic included would have reduced head scratching a little, but overall no problems. It is perfect for the intended use. Oh yes, is there an internal diode to protect the operating circuit from the reverse EMF when the relay is shut off.
MASTER RELAY 111-226
Please note, Aircraft Spruce's personnel are not certified aircraft mechanics and can only provide general support and ideas, which should not be relied upon or implemented in lieu of consulting an A&P or other qualified technician. Aircraft Spruce assumes no responsibility or liability for any issue or problem which may arise from any repair, modification or other work done from this knowledge base. Any product eligibility information provided here is based on general application guides and we recommend always referring to your specific aircraft parts manual, the parts manufacturer or consulting with a qualified mechanic.
Per the manufacturer, the answer is no. The terminal going to the coil is the negative side and should go to the master switch, and the positive side of the coil is common to the power terminal.
Regarding part number 11-03161, the maximum inrush rating is 150 amps and the continuous duty rating is 80 amps.
Per the manufacturer, no it does not. Regarding part numbers 11-03161 / 11-05799.
We have added the drawing to the "Documents" tab of this web page. Please review it there.
The 70-111226-5B1 is a 12V continuous duty solenoid, so therefore the coil is rated at approximately 9 watts. Since P= IV. Or, 9=I (12). So for a 12 volt system, the current is 0.75 amps
No, because the starter circuit requires high amperage we do not recommend using this relay.
No, these master relays are intended for use on experimental aircraft only.
The single terminal version is the 12 volt. If you click for the full size image, you will see each image is watermarked with the sku for that product.
"Recommended mounting with cap down" per TDS.
This is shown cap down on our website, the writing is not upside down.